New service for professionals

Energy EfficiencIA Studies
for Professionals

Your client asks you for the certificate. We produce the complete report + XML for registration.
You just read, sign, and bill.

< 24h
Report delivery
XML
Ready for registration
90%
Less work in CE3X

Certifying is tedious. And you know it.

You're a certifying technician. Your job is to sign, not to lay out reports.
But every certificate eats up hours of mechanical work.

📸

Photos, measurements, sketches

Taking field data, organizing photos, drawing sketches, cataloging rooms. Every dwelling takes 2-3 hours before you sit down at the computer.

💻

CE3X: data point by data point

Entering each enclosure, each opening, each installation. Verifying thermal transmittances, surfaces, orientations. Mechanical and repetitive work.

📄

A report no one reads

Laying out the PDF, inserting photos, filling in tables, writing recommendations. All so the client only looks at the energy label letter.

🏛️

Registration with regional ministry

Preparing the XML, uploading it to the electronic registry, waiting for validation. Yet another procedure that eats up your time.

Three steps. You just sign.

You send us the field data and we produce everything: report, Excel, XML for registration, and photo set.

1

You send the data

Photos of the property, measurements or sketches, and an audio or text describing the project. What you already do during the visit.

2

We produce everything

In less than 24h you receive: laid-out PDF report, Excel with technical data, pre-filled XML for CE3X, photo set, and checklist.

3

You sign and bill

You review the report (10 min), import the XML into CE3X, generate the final version, register with the regional ministry, and bill your client.

Everything you need. Nothing to lay out.

📋
Professional PDF report
Laid out, with cover page, cataloged photos, tables of building enclosures, openings, installations, energy rating, and improvement measures. Ready to deliver to your client.
📊
Excel with technical data
All report tables in editable format. 4 sheets: thermal envelope, installations, energy rating, and summary. Compatible with CE3X and CERMA.
XML for registration with regional ministry
XML file compliant with the CTE/MITECO v2.1 schema. Pre-filled with all the building's data. Importable into CE3X. Saves you 90% of data entry. Nobody else offers this.
📸
Photo set
Photos cataloged by room and construction element. Numbered, labeled, and ready for the report.
🎨
Before/after AI renders
Visualizations of the proposed improvement measures. Your client sees how their dwelling would look after the energy renovation.
Critical points checklist
Verification list with detected deficiencies, thermal bridges, dampness, obsolete installations. So nothing slips by.

This is what a complete study looks like.

Anonymized real project. Single-family dwelling of 72 m² built (64 m² usable), climate zone A3. Download the free sample.

XML ready for registration. Nobody else offers this.

We deliver an XML file compliant with the official CTE/MITECO v2.1 schema with all the building's data pre-filled. You import it into CE3X, calculate, and you're done.

Real fragment of the XML delivered

Compliant with the official CTE/MITECO v2.1 schema — Validatable at visorxml.codigotécnico.org

<!-- Informe de Evaluación Energetica del Edificio --> <DatosEnergeticosDelEdificio version="2.1"> <IdentificacionEdificio> <TipoDeEdificio>ViviendaUnifamiliar</TipoDeEdificio> <ZonaClimatica>A3</ZonaClimatica> <NormativaVigente>Anterior a NBE-CT-79</NormativaVigente> <NombreDelProcedimiento>CE3X</NombreDelProcedimiento> </IdentificacionEdificio> <DatosEnvolventeTermica> <CerramientosOpacos> <Cerramiento> <Nombre>Muro exterior parte vieja</Nombre> <Tipo>Fachada</Tipo> <Superficie>24.50</Superficie> <Transmitancia>2.30</Transmitancia> <Composicion> <Capa nombre="Piedra natural" espesor="0.55"/> </Composicion> </Cerramiento> </CerramientosOpacos> </DatosEnvolventeTermica> <InstalacionesTermicas> <!-- ACS, calefaccion, refrigeracion... --> </InstalacionesTermicas> <Calificacion> <!-- Se genera en CE3X tras calculo --> </Calificacion> </DatosEnergeticosDelEdificio>

Our XML includes all sections: DatosDelCertificador, IdentificacionEdificio, DatosGeneralesyGeometria, DatosEnvolventeTermica (enclosures + openings), InstalacionesTermicas, Calificacion, and MedidasDeMejora.

The flow: from our XML to the energy label

Our XML
Import into CE3X, calculate, and done
Regional ministry registration
Official label

Compatible with CE3X, CE3, and CERMA (programs recognized by MITECO) — Validatable in the CTE XML Viewer from IETcc-CSIC

6 reasons to delegate the report.

🤖
AI + technical experience
We combine artificial intelligence with real technical knowledge. It's not a template: each report is produced with real data from the property.
Delivery in less than 24h
You send us the data today, tomorrow you have the complete report. No delays, no excuses.
Verified quality
Every report goes through technical review. The data is consistent, the tables match, the XML validates.
XML for registration
Nobody else delivers a pre-built XML compliant with CTE/MITECO v2.1. It saves you 90% of the work in CE3X.
🏷️
Your brand, your report
The report carries your certifier details. We are invisible. Your client only sees your professional work.
💵
Price that pays off
Less than what your time is worth doing it yourself. Every hour you save is an hour you can bill on another visit.

From visit to registration in 4 steps

Visit and data

You make the visit to the property. You send us photos, measurements, and a description by audio or text.

We produce everything

In less than 24h you receive: PDF report, Excel, pre-filled XML, cataloged photos, and checklist.

You review in CE3X

You import our XML into CE3X, verify data (10 min), calculate the energy rating, and export the final XML.

You register and bill

You upload the XML to the regional ministry's electronic registry. You obtain the official label. You bill your client.

Try it with your next certificate.

Send us the data of your next project. No surprises or hidden costs: we agree on the price, you transfer, and in 24 hours you have the complete study ready to sign.

Or email us directly: studio@eficiencial.com · +34 674 786 386

What is CE3X and why do you need the XML?

CE3X is the official program recognized by MITECO for the energy certification of existing buildings. Our service eliminates 90% of the mechanical work by delivering a pre-filled XML with all the building's data.

What does the XML we deliver contain? +
  • Certifier data — Name, NIF, qualification, contact
  • Building identification — Address, type, year, climate zone
  • Geometry — Habitable surface, compactness, volume
  • Thermal envelope — Building enclosures with thermal transmittances and compositions
  • Openings — Windows and doors with solar factor and permeability
  • Thermal installations — DHW, heating, cooling
  • Improvement measures — Renovation proposals with savings estimates
  • Compatible with CE3X, CE3, and CERMA
How does registration with the Regional Ministry work? +

Once you generate the final XML from CE3X, you upload it to the electronic registry of your autonomous community. In the Canary Islands: procedure 3137 — Registration in the Energy Efficiency Certificates Registry (SICAC).

The XML can be pre-validated in the CTE XML Viewer from IETcc-CSIC.

The usual certification process is laborious: the technician visits the property, takes data on the thermal envelope (walls, roofs, floors, openings), the thermal installations (heating, cooling, DHW), and the building's geometric conditions. Then they manually enter each data point in CE3X: each enclosure with its thermal transmittance, each opening with its solar factor, each installation with its performance.

Our pre-filled XML compliant with the CTE/MITECO v2.1 schema contains all the necessary sections: DatosDelCertificador, IdentificacionEdificio, DatosGeneralesyGeometria, DatosEnvolventeTermica (opaque enclosures + openings), InstalacionesTermicas (DHW, heating, cooling), InstalacionesIluminacion, Calificación, and MedidasDeMejora. The technician only has to import, verify values, calculate, and export.

Once the technician generates the final XML from CE3X, they upload it to the electronic registry of their autonomous community to register the certificate in the official registry. In the Canary Islands, the procedure is carried out at the electronic registry of the Government of the Canary Islands (procedure 3137 — Registration in the Energy Efficiency Certificates Registry, SICAC). The XML can be pre-validated in the CTE XML Viewer from the Eduardo Torroja Institute (IETcc-CSIC) to ensure it complies with the official schema before registration.

Request quote →